Export limit exceeded: 14675 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 23022 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (23022 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2012-10028 | 1 Netwin | 1 Surgeftp | 2026-04-15 | N/A |
| Netwin SurgeFTP version 23c8 and prior contains a vulnerability in its web-based administrative console that allows authenticated users to execute arbitrary system commands via crafted POST requests to `surgeftpmgr.cgi`. This can lead to full remote code execution on the underlying system. | ||||
| CVE-2025-65001 | 1 Fujitsu | 1 Fbiosdrv | 2026-04-15 | 8.2 High |
| Fujitsu fbiosdrv.sys before 2.5.0.0 allows an attacker to potentially affect system confidentiality, integrity, and availability. | ||||
| CVE-2025-64129 | 1 Zenitel | 1 Tciv-3+ | 2026-04-15 | 7.6 High |
| Zenitel TCIV-3+ is vulnerable to an out-of-bounds write vulnerability, which could allow a remote attacker to crash the device. | ||||
| CVE-2025-64128 | 1 Zenitel | 1 Tciv-3+ | 2026-04-15 | 10 Critical |
| An OS command injection vulnerability exists due to incomplete validation of user-supplied input. Validation fails to enforce sufficient formatting rules, which could permit attackers to append arbitrary data. This could allow an unauthenticated attacker to inject arbitrary commands. | ||||
| CVE-2025-64127 | 1 Zenitel | 1 Tciv-3+ | 2026-04-15 | 10 Critical |
| An OS command injection vulnerability exists due to insufficient sanitization of user-supplied input. The application accepts parameters that are later incorporated into OS commands without adequate validation. This could allow an unauthenticated attacker to execute arbitrary commands remotely. | ||||
| CVE-2025-64126 | 1 Zenitel | 1 Tciv-3+ | 2026-04-15 | 10 Critical |
| An OS command injection vulnerability exists due to improper input validation. The application accepts a parameter directly from user input without verifying it is a valid IP address or filtering potentially malicious characters. This could allow an unauthenticated attacker to inject arbitrary commands. | ||||
| CVE-2024-42757 | 1 Asus | 1 Rt-n15u Firmware | 2026-04-15 | 9.8 Critical |
| Command injection vulnerability in Asus RT-N15U 3.0.0.4.376_3754 allows a remote attacker to execute arbitrary code via the netstat function page. | ||||
| CVE-2025-64109 | 1 Cursor | 1 Cursor | 2026-04-15 | 8.8 High |
| Cursor is a code editor built for programming with AI. In versions and below, a vulnerability in the Cursor CLI Beta allowed an attacker to achieve remote code execution through the MCP (Model Context Protocol) server mechanism by uploading a malicious MCP configuration in .cursor/mcp.json file in a GitHub repository. Once a victim clones the project and opens it using Cursor CLI, the command to run the malicious MCP server is immediately executed without any warning, leading to potential code execution as soon as the command runs. This issue is fixed in version 2025.09.17-25b418f. | ||||
| CVE-2025-20617 | 2026-04-15 | N/A | ||
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If an attacker logs in to the affected product with an administrative account and manipulates requests for a certain screen operation, an arbitrary OS command may be executed. This vulnerability was reported on a different screen operation from CVE-2025-26856. | ||||
| CVE-2012-10029 | 1 Nagios | 4 Nagios, Nagios Xi, Xi and 1 more | 2026-04-15 | N/A |
| Nagios XI Network Monitor prior to Graph Explorer component version 1.3 contains a command injection vulnerability in `visApi.php`. An authenticated user can inject system commands via unsanitized parameters such as `host`, resulting in remote code execution. | ||||
| CVE-2025-20295 | 1 Cisco | 1 Unified Computing System Manager | 2026-04-15 | 6 Medium |
| A vulnerability in the CLI of Cisco UCS Manager Software could allow an authenticated, local attacker with administrative privileges to read or create a file or overwrite any file on the file system of the underlying operating system of an affected device, including system files. This vulnerability is due to insufficient input validation of command arguments supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input to the affected command. A successful exploit could allow the attacker to read or create a file or overwrite any file on the file system of the underlying operating system of the affected device, including system files. To exploit this vulnerability, the attacker must have valid administrative credentials on the affected device. | ||||
| CVE-2025-20292 | 1 Cisco | 2 Nx-os, Unified Computing System Manager | 2026-04-15 | 4.4 Medium |
| A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute a command injection attack on the underlying operating system of an affected device. To exploit this vulnerability, the attacker must have valid user credentials on the affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by entering crafted input as the argument of an affected CLI command. A successful exploit could allow the attacker to read and write files on the underlying operating system with the privileges of a non-root user account. File system access is limited to the permissions that are granted to that non-root user account. | ||||
| CVE-2024-43648 | 2026-04-15 | 8.8 High | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||