| CVE-2026-4832 | 1 Schneider-electric | 25 Easergy P14x, Easergy P24x, Easergy P341 and 22 more | 2026-04-17 | N/A |
| CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port. | ||||
| CVE-2026-1286 | 1 Schneider-electric | 2 Ecostruxure Foxboro Dcs Control Software, Foxboro Dcs | 2026-04-17 | 6.5 Medium |
| CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. | ||||
| CVE-2026-2273 | 1 Schneider-electric | 1 Ecostruxure Automation Expert | 2026-04-17 | 8.2 High |
| CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file. | ||||
| CVE-2025-11566 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. | ||||
| CVE-2025-54926 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.2 High |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed. | ||||
| CVE-2025-6625 | 1 Schneider-electric | 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more | 2026-04-15 | 7.5 High |
| CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2024-8938 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 8.1 High |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. | ||||
| CVE-2024-9002 | 1 Schneider-electric | 1 Easergy Studio | 2026-04-15 | 7.8 High |
| CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity, and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries | ||||
| CVE-2025-11565 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload. | ||||
| CVE-2024-8935 | 1 Schneider-electric | 3 Modicon M340 Bmxp341000, Modicon Mc80 Bmkc8020301, Modicon Momentum Unity M1e Processor | 2026-04-15 | 7.5 High |
| CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks. | ||||
| CVE-2024-8936 | 1 Schneider-electric | 1 Modicon M340 | 2026-04-15 | 6.5 Medium |
| CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. | ||||
| CVE-2025-11567 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured. | ||||
| CVE-2025-54924 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint. | ||||
| CVE-2025-54925 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||
| CVE-2024-8518 | 1 Schneider-electric | 1 Zelio Soft 2 | 2026-04-15 | 3.3 Low |
| CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user. | ||||
| CVE-2024-10498 | 1 Schneider-electric | 1 Powerlogic Hdpm6000 | 2026-04-15 | 6.5 Medium |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality. | ||||
| CVE-2024-8530 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 5.9 Medium |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||||
| CVE-2025-54927 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 4.9 Medium |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system. | ||||