| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A stack-based buffer overflow vulnerability exists in Synactis PDF In-The-Box ActiveX control (PDF_IN_1.ocx), specifically the ConnectToSynactis method. When a long string is passed to this method—intended to populate the ldCmdLine argument of a WinExec call—a strcpy operation overwrites a saved TRegistry class pointer on the stack. This allows remote attackers to execute arbitrary code in the context of the user by enticing them to visit a malicious webpage that instantiates the vulnerable ActiveX control. The vulnerability was discovered via its use in third-party software such as Logic Print 2013. |
| LanSend 3.2 contains a buffer overflow vulnerability in the Add Computers Wizard file import functionality that allows remote attackers to execute arbitrary code. Attackers can craft a malicious payload file to trigger a structured exception handler (SEH) overwrite and execute shellcode when importing computers from a file. |
| A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. |
| A vulnerability in Cisco Secure Firewall Adaptive Security Appliance (ASA) Software and Cisco Secure Firewall Threat Defense (FTD) Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system with root-level privileges. To exploit this vulnerability, the attacker must have valid administrative credentials.
This vulnerability is due to insufficient input validation of commands that are supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input for specific commands. A successful exploit could allow the attacker to execute commands on the underlying operating system as root. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the wireless network configuration file via a crafted HTTP request. |
| Improper input validation in IOMMU could allow a malicious hypervisor to reconfigure IOMMU registers resulting in loss of guest data integrity. |
| User-controlled chunkSize metadata from MongoDB lacks appropriate validation allowing malformed GridFS metadata to overflow the bounding container. |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in rethinkdb.This issue affects rethinkdb: before 2.4.4. |
| SummaryThis advisory addresses a security vulnerability in Mautic where unpublished page previews could be accessed by unauthenticated users and potentially indexed by search engines. This could lead to the unintended disclosure of draft content or sensitive information.
Unauthorized Access to Unpublished Page Previews: The page preview functionality for unpublished content, accessible via predictable URLs (e.g., /page/preview/1, /page/preview/2), lacked proper authorization checks. This allowed any unauthenticated user to view content that was not yet intended for public release, and allowed search engines to index these private preview URLs, making the content publicly discoverable.
MitigationMautic has patched this vulnerability by enforcing proper permission checks on preview pages. Users should upgrade to the patched version of Mautic or later. |
| Out-of-bounds Read vulnerability in ASR1903、ASR3901 in ASR Lapwing_Linux on Linux (nr_fw modules). This vulnerability is associated with program files Code/nr_fw/DLP/src/NrCgi.C.
This issue affects Lapwing_Linux: before 2025/11/26. |
|
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:
SEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay
. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.
|
| Improper Validation of Specified Quantity in Input vulnerability in The Events Calendar BookIt allows Manipulating Hidden Fields.This issue affects BookIt: from n/a through 2.4.0. |
| An unauthorised attacker within bluetooth range may use an improper validation during the BLE connection request to deadlock the affected devices. |
| A buffer overflow in the AMD Secure Processor (ASP) bootloader could allow an attacker to overwrite memory, potentially resulting in privilege escalation and arbitrary code execution. |
| Improper input validation in system management mode (SMM) could allow a privileged attacker to overwrite stack memory leading to arbitrary code execution. |
| Improper access control in AMD Secure Encrypted Virtualization (SEV) firmware could allow a malicious hypervisor to bypass RMP protections, potentially resulting in a loss of SEV-SNP guest memory integrity. |
| Out-of-bounds Read in Shelly Pro 3EM (before v1.4.4) allows Overread Buffers. |
| A vulnerability was detected in Axosoft Scrum and Bug Tracking 22.1.1.11545. This issue affects some unknown processing of the component Add Work Item Page. The manipulation of the argument Title results in csv injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A Heap-based Buffer Overflow vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures. |
| Panasonic IR Control Hub (IR Blaster) versions 1.17 and earlier may allow an attacker with physical access to load unauthorized firmware onto the device. |