| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. |
| Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings. |
| User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| Under certain circumstances the Linux users credentials may be recovered by an authenticated user. |
| Vulnerability in Spotfire Spotfire Analyst, Spotfire Spotfire Server, Spotfire Spotfire for AWS Marketplace allows In the case of the installed Windows client: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code.This requires human interaction from a person other than the attacker., In the case of the Web player (Business Author): Successful execution of this vulnerability via the Web Player, will result in the attacker being able to run arbitrary code as the account running the Web player process, In the case of Automation Services: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code via Automation Services..This issue affects Spotfire Analyst: from 12.0.9 through 12.5.0, from 14.0 through 14.0.2; Spotfire Server: from 12.0.10 through 12.5.0, from 14.0 through 14.0.3, from 14.2.0 through 14.3.0; Spotfire for AWS Marketplace: from 14.0 before 14.3.0. |
| Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL. |
| A vulnerability has been found in FAST/TOOLS and CI Server. The affected products have built-in accounts with no passwords set. Therefore, if the product is operated without a password set by default, an attacker can break into the affected product.
The affected products and versions are as follows:
FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
CI Server R1.01.00 to R1.03.00 |
| Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data. |
| runofast Indoor Security Camera for Baby Monitor has a default password of password for the root account. This allows access to the /stream1 URI via the rtsp:// protocol to receive the video and audio stream. |
| A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands. |
| A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier. |
| Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0. |
| A security vulnerability in HCL Compass can allow attacker to gain unauthorized database access. |
| CWE-250: Execution with Unnecessary Privileges |
| CWE-250: Execution with Unnecessary Privileges |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |